Step1b. Using the provided Allen wrench, loosen the set
screw several turns to allow installation of the downrod.
read the downrod into the motor coupling until it stops
turning. is will take at least four and a half full turns.
Step1c. Tighten the set screw securely with the provided
Allen wrench to ensure safe operation of your fan.
IMPORTANTSAFETYINFORMATION!
Beforestartingtheinstallationofyourceilingfan,installthethreaded
downrodintothemotorcouplingandlocktheassembly
Prepareforfaninstallationasfollows:
Step1a. Route the wires from the motor through the
Perma
Lock™ downrod and ball assembly.
Tip:edownrodhasataperedthreadthatisdesigned
tolockcompletelywhencorrectlyinstalled.
CAUTION: Failure to fully lock in the downrod
before securely tightening the Allen set screw may
cause the fan to separate from the downrod during
normaloperation!
FAN INSTALLATION
FAN PREPARATION
CEILING HARDWARE
GETTING STARTED
Unpacking: Before assembling and installing your ceiling fan, remove all parts from the shipping cartons and check them against
the parts listed here. Before discarding packaging material, be certain that all parts have been removed.
PERMA*LOCK HARDWARE
AllenSetScrew
1/4-20x1/4”
(pre-installed)
3mm
AllenWrench
Downrod&Ball
Assembly
MotorWires
GroundWire
Downrod
&BallAssembly
Motor
Coupling
Allen
SetScrew
Tapered
read
InstallingaNewCeilingFixtureOutletBox
If you do not have an existing fixture located where you wish
to place your Casablanca fan, an approved ceiling fixture outlet
box must be installed and wired.
Warning:To reduce the risk of fire, electrical
shock, or personal injury,mount to outlet box
markedacceptableforceilingfansupportusingthe
mountinghardwareprovidedwiththeoutletbox.
WireNut(4)
Crossbar
Mounting
Bracket
UsingExistingCeilingFixtureOutletBox
After turning the power OFF at its source (either circuit breaker
or fuse box), lower the old fixture and disconnect the wiring.
Check the ceiling fixture outlet box to be sure that it is marked
Approved for ceiling fan mounting’. If it is not, a new box must
be installed.
2-1/4x8-32Rounded
HeadScrew(2)
ADDITIONALHARDWARE
1x8-32rounded
headscrew(2)
FlatWasher(2)
IMPORTANTNOTE-CEILINGHEIGHT
isfanisdesignedforinstallationonceilingswithaminimumheightof10feetfromtheoor.
elargebladesrequiretheuseofthe12”extensionpoletoallowforproperairowandventilation.